Petroleum Well Control Equipment Co., Ltd.(PWCE)

PWCE Express Oil and Gas Group Co., LTD.

Seadream Offshore Technology Co., LTD.

Wellcontrol Equipment

  • API 16D Certified BOP Closing Unit

    API 16D Certified BOP Closing Unit

    A BOP accumulator unit (also known as a BOP closing unit) is one of the most critical components of blowout preventers. Accumulators are placed in hydraulic systems for the purpose of storing energy to be released and transferred throughout the system when it is needed to accomplish specific operations. BOP accumulator units also provide hydraulic support when pressure fluctuations occur. These fluctuations happen often in positive displacement pumps due to their operational functions of trapping and displacing fluid.

  • API 16 RCD Certified Rotary Preventer

    API 16 RCD Certified Rotary Preventer

    The rotary blowout preventer is installed on top of the annular BOP. During underbalanced drilling operations and other pressure drilling operations, it serves the purpose of diverting flow by sealing the rotating drill string. When used in conjunction with drilling BOP, drill string check valves, oil-gas separators, and snubbing units, it allows for safe pressurized drilling and snubbing operations. It plays a vital role in special operations such as liberating low-pressure oil and gas layers, leak-proof drilling, air drilling, and snubbing well repairs.

  • Shaffer Type BOP part shear ram assembly

    Shaffer Type BOP part shear ram assembly

    · In accordance with API Spec.16A

    · All the parts are original or interchangeable

    · Reasonable structure, easy operation, long life of core

    · Adapt to a wide range, capable of sealing pipe string with nominal path shapes, better performance by combining with ram blowout preventer in the use.

    A shear ram can cut pipe in the well, blindly close the wellhead, and also be used as a blind ram when there is no pipe in the well. The installation of the shear ram is the same as the original ram.

  • Shaffer Type Variable Bore Ram Assembly

    Shaffer Type Variable Bore Ram Assembly

    Our VBR rams are suitable for H2S service per NACE MR-01-75.

    100% interchangeable with type U BOP

    Longer service life

    2 7/8”-5” and 4 1/2” – 7” for 13 5/8” – 3000/5000/10000PSIBOP are available.

  • BOP part U type shear ram assembly

    BOP part U type shear ram assembly

    The large frontal area on the blade face seal reduces pressure on the rubber and increases service life.

    Type U SBRs can cut pipe numerous times without damage to the cutting edge.

    The single-piece body incorporates an integrated cutting edge.

    H2S SBRs are available for critical service applications and include a blade material of hardened high alloy suitable for H2S service.

    The type U shearing blind ram has a single-piece body with an integrated cutting edge.

  • BOP Seal Kits

    BOP Seal Kits

    · Longer service life, Increase service life by 30% on average.

    · Longer storage time, the storage time can be increased to 5 years, under the shading conditions, the temperature and humidity should be controllable

    · Better high/low-temperature resistant performance and better sulfur-resistant performance.

  • GK GX MSP Type Annular BOP

    GK GX MSP Type Annular BOP

    Application: onshore drilling rig & offshore drilling platform

    Bore Sizes: 7 1/16” — 21 1/4”  

    • Working Pressures: 2000 PSI — 10000 PSI

    • Body Styles: Annular

    • Housing Material: Casting 4130 & F22

    • Packer element material: Synthetic rubber

    • Third party witness and inspection report available: Bureau Veritas (BV), CCS, ABS, SGS etc.

  • Type T-81 Blowout Preventer For Well Control System

    Type T-81 Blowout Preventer For Well Control System

    • Application: Onshore drilling rig

    • Bore Sizes: 7 1/16” — 9”

    • Working Pressure: 3000 PSI  — 5000 PSI

    • Ram style: single ram, double rams & triple rams

    • Housing MaterialForging 4130

    • Third-party witness and inspection report available: Bureau Veritas (BV), CCS, ABS, SGS, etc.

    Manufactured in accordance with API 16A, Fourth Edition & NACE MR0175.

    • API monogrammed and suitable for H2S service as per NACE MR-0175 standard

  • Blowout Preventer Shaffer Type Lws Double Ram BOP

    Blowout Preventer Shaffer Type Lws Double Ram BOP

    Application: Onshore

    Bore Sizes: 7 1/16” & 11”

    Working Pressures: 5000 PSI

    Body Styles: Single & Double

    Material: Casing 4130

    Third party witness and inspection report available: Bureau Veritas (BV), CCS, ABS, SJS etc.

    Manufactured in accordance with: API 16A, Fourth Edition & NACE MR0175.

    API monogrammed and suitable for H2S service as per NACE MR-0175 standard

  • Diverters for well-control while drilling in the surface layer

    Diverters for well-control while drilling in the surface layer

    Diverters are primarily used for well-control while drilling in the surface layer in the exploration of oil and gas. Diverters are used together with hydraulic control systems, spools and valve gates. The streams (liquid, gas) under control are transmitted to safe zones along a given route to ensure the security of well operators and equipment. It may be used to seal Kelly, drill pipes, drill pipe joints, drill collars and casings of any shape and size, at the same time it can divert or discharge the streams in well.

    Diverters offer an advanced level of well control, improving safety measures while boosting drilling efficiency. These versatile devices boast a resilient design that allows for swift and effective responses to unexpected drilling challenges such as overflows or gas influxes.

  • Choke Manifold and kill Manifold

    Choke Manifold and kill Manifold

    ·Control pressure to prevent overflow and blowout.

    ·Reduce wellhead casing pressure by relief function of the choke valve.

    ·Full-bore and two-way metal seal

    ·The internal of the choke is constructed with hard alloy, exhibiting a high level of resistance to erosion and corrosion.

    ·The relief valve helps to reduce casing pressure and protect BOP.

    ·Configuration type: single-wing, double-wing, multiple-wing or riser manifold

    ·Control type: manual, hydraulic, RTU

    Kill Manifold

    ·Kill manifold is mainly used to kill well, prevent fire and assist in fire extinction.

  • Type S Pipe Ram Assembly

    Type S Pipe Ram Assembly

    The Blind Ram is used for single or double Ram Blowout Preventer(BOP). It can be closed when the well is without the pipeline or blowout.

    ·Standard: API

    ·Pressure: 2000~15000PSI

    ·Size: 7-1/16″ to 21-1/4″

    · U type, type S Available

    · Shear/ Pipe/Blind/variable Rams